VDSDB20001ST

Part number
VDSDB20001ST
EAN
Unit
Each
Long description
A differential controlled sequence valve, also known as a pre-tank valve, is a valve that will open at a preset pressure. These are mainly used in multi-cylinder systems, where the sending in or out has to happen in a certain order.
Product details
  • High pressure and medium volume flow
  • For inline mounting
  • To be used as sequential switching
  • Version: individual parts in housing
  • Works from D to C
  • Free flow from C to D
  • The pressure setting depends on the load in C
  • No external leakage connection
Includes
  • Steel housing
  • Differential controlled pressure relief valve
  • Bypass check valve for free return
Max. flow rate
120 l/min
Max working pressure
350 BAR
Adjustable pressure range
100-350 BAR
Adjustment type
Socket screw
Connection thread diameter
3/4 Inch
Connection 2, thread diameter
3/4 Inch
Housing length
90 mm
Housing width
40 mm
Housing height
90 mm
Cartridge length
58 mm
Mounting holes diameter
10,5 mm