Product details | - Checking, reducing or increasing the pre-charge pressure of hydraulic accumulators
- The filling system is connected to the gas cylinder pressure reducer
- The pressure of the gas cylinder must always be higher than the fill pressure of the accumulator
- Only fill with nitrogen, never oxygen or compressed air
- For more information on special pressure reducers and gas cylinders, please contact your technical gas supplier
- For accumulators with 5/8" UNF connections, add adaptor 20213000223.
- LAV9DP100: Accumulator M28x1.5
- Nitrogen cylinder W24.32 x 1 1/4"
- Max operating pressure : 360 bar
| |
---|