MEC9000PL

Part number
MEC9000PL
EAN
Unit
Each
Details
  • The MEC II-series pumps have an automatic protection system. So, for example, if a vane breaks, the rotor and rotor housing can be protected by the rotor—including the flange mountings—being pushed downwards
  • Pumps with a "ballast system", identified by B at the end of the item number (e.g. MEC9000MB) have a longer operating time in vacuum operation
  • The operating time at -0.95 bar lasts from 8 minutes (standard) up to a maximum of 15 minutes. Continuous operation is permissible at -0.6 bar.
  • MEC II-series pumps are supplied with long-life (heat-resistant) vanes as standard
  • MEC II-series pumps feature a temperature meter to enable the temperature to be read during operation
  • A maintenance hatch can be used to determine the wear condition of the vanes, indicating when the vanes need to be replaced
  • Each pump is subjected to a final check in the factory, in which the vacuum, compression and lubrication are tested, among other factors
  • A test report relating to the serial number is drawn up for each pump
Application range
These vacuum pumps with vanes are mainly used in agriculture for filling and emptying slurry tanks
Properties
These pumps can generate both positive pressure and vacuum
Technical info
  • Composition of item numbers: MEC= series, 9000= type, P= pulley drive, B= ballast system, A= automatic lubrication
  • On pumps without automatic lubrication (no "A" in the item number), the pump is equipped with a forced lubrication system that is adjusted using dripper nozzles Automatic lubrication available on request
  • On pumps without automatic lubrication, the quantity of lubrication oil is set in the factory and cannot be changed without a tool
  • In the case of forced lubrication, as with automatic lubrication, the function must be checked at all times during operation
  • Pumps with pulley drive rotate clockwise. Counterclockwise rotation with 'L' in the item number or available on request
  • The direction of rotation is determined when the axle to be driven is aligned with the observer
  • Oil to be used for lubricating the vanes: genuine oil from B. P. (item number BP5070)
Benefits
  • Minimum repair costs thanks to the unique automatic protection system
  • As pumps from B.P. are tested, inspected and packaged with the utmost care, trouble-free start-up is 100% guaranteed
Nominal volume flow rate
9030 l/min
Drive type
Pulley
Direction of rotation
Counter-clockwise (CCW)
Ballast air injection system
No
Consists of
  • Without pressure relief valve (item 0200013) and vacuum valve (item 0155513)
  • The pumps are delivered without lubrication oil (item BP5070)
  • Without pulley
Lubrication system type
Forced
Vane type
Long life
Crash protection system
Yes
Max vacuum
0.95 BAR
Max. relative pressure
1.5 BAR
Power requirement for max. pressure
25 kW
Power requirement for max. vacuum
16 kW
D,PDiameter of hose connection
80 mm
Safety valve connection diameter
2 Inch
Depression valve connection diameter
1-1/2 Inch
ETotal length
535 mm
OTotal width
390 mm
GHeight
575 mm
FMounting holes diameter
22 mm
B,LMounting holes distance
  • 189 mm
  • 246 mm
AMounting holes to shaft end distance
205 mm
CMounting holes to end distance
141 mm
MShaft centre to left side end distance
195 mm
NShaft centre to right side end distance
195 mm
IShaft centre to bottom distance
164 mm
Shaft length
63 mm
Max. shaft rotation
1400 r/min
Reservoir capacity
2.5 l
Weight
131 kg