Part number | AV02001 | |
---|---|---|
EAN | ||
Unit | Each | |
Long description | A loading valve, also called unloading valve or constant pressure valve, provides a constant set pressure in a secondary system. Preferably in combination with an accumulator. This valve opens at 15% pressure difference from the set pressure and relieves the pump to the return. The check valve will keep port U pressurised and the coupled accumulator will absorb pressure fluctuations or sudden volume demand in the secondary system. Show more | |
Product details |
| |
Includes |
| |
Max. flow rate | 20 l/min | |
Max working pressure | 350 BAR | |
Connection type | Thread | |
Connection thread type | Inch | |
Connection thread diameter | 1/4 Inch | |
Connection 2, thread type | Metric | |
Housing length | 59 mm | |
Housing width | 38.5 mm | |
Housing height | 90 mm | |
Total height | 169.4 mm | |
Mounting holes diameter | 10 mm | |
Extra info |
|