JET Self-priming centrifugal pumps

Browse to product table

Interested in buying products?

Want to know more about the prices or order directly? This is possible when you are affiliated with a dealer in your area. Do you want to sell products via Kramp as a dealer? Then sign up!

  • Tailored advice from our specialists
  • More than 500.000 products
  • Up-to-date information on current stock and delivery times
Details
Excellent suction capacity, including with air bubbles in water
Application range
  • For water supply to residential installations
  • For small-scale agriculture and horticulture, and for wherever the function of a self-priming pump is required
Properties
  • Self-aspirating
  • Motor protection class: IP 44
  • Clamp strip protection class: IP 55 for models with single-phase motor
Technical info
Pumped liquid: clean, no abrasive contents, non-viscous, non-aggressive, non-crystallising and chemically neutral, closely approximating to the properties of water
Benefits
Reliable

Interested in buying products?

Want to know more about the prices or order directly? This is possible when you are affiliated with a dealer in your area. Do you want to sell products via Kramp as a dealer? Then sign up!

  • Tailored advice from our specialists
  • More than 500.000 products
  • Up-to-date information on current stock and delivery times
Product
Unit

Housing material

Nominal volume flow rate

Max. volume flow rate

Rated voltage

Frequency

Motor power output (P2)

Nominal current

Insulation class according to IEC

Insulation class

Rotational speed

Max. medium temperature (continuous)

Min. medium temperature (continuous)

Max delivery height

Thread type of suction side connection

Thread diameter of suction side connection

Thread diameter of delivery side connection

Total width

Total length

Power consumption

Current In nominal

Frequency

Insulation class

Length

Material housing

Max. input power

Temperature max.

Temperature min.

IP

Nominal flow

Connection

Rotational speed

Type

Voltage

Width

Discharge head at nom. flow rate

Height

Each
Cast iron
2,1 m³/h
3,6 m³/h
220-240 V
50 Hz
0,6 kW
3,8 A
F
44
2850 r/min
40 °C
0 °C
47 m
BSPP
1 Inch
1 Inch
178 mm
395 mm
0,85 kW
Each
Cast iron
3,1 m³/h
4,8 m³/h
220-240 V
50 Hz
0,75 kW
4,2 A
F
44
2850 r/min
40 °C
0 °C
36,2 m
BSPP
1 Inch
1 Inch
178 mm
395 mm
0,94 kW
Each
Cast iron
2,6 m³/h
3,6 m³/h
220-240 V
50 Hz
0,75 kW
5,1 A
F
44
2850 r/min
40 °C
0 °C
53,8 m
BSPP
1 Inch
1 Inch
178 mm
414 mm
1,18 kW
Each
Cast iron
3,4 m³/h
4,8 m³/h
220-240 V
50 Hz
1,02 kW
6,6 A
F
44
2850 r/min
40 °C
0 °C
48,3 m
BSPP
1 Inch
1 Inch
178 mm
414 mm
1,49 kW
Each
Cast iron
2,9 m³/h
4,5 m³/h
220-240 V
50 Hz
1,13 kW
7,2 A
F
44
2850 r/min
40 °C
0 °C
60,5 m
BSPP
1-1/4 Inch
1 Inch
210 mm
558 mm
1,6 kW
Each
Cast iron
7,2 m³/h
10,5 m³/h
220-240 V
50 Hz
1,5 kW
9 A
F
44
2850 r/min
40 °C
0 °C
41 m
BSPP
1-1/2 Inch
1-1/4 Inch
214 mm
521 mm
2 kW
Each
Cast iron
4,2 m³/h
7,2 m³/h
220-240 V
50 Hz
1,88 kW
10 A
F
44
2850 r/min
40 °C
0 °C
62 m
BSPP
1-1/4 Inch
1 Inch
210 mm
632 mm
2,2 kW
Each
Cast iron
7,2 m³/h
10,5 m³/h
220-240 V
50 Hz
2,25 kW
12 A
F
44
2850 r/min
40 °C
0 °C
51 m
BSPP
1-1/2 Inch
1-1/4 Inch
214 mm
595 mm
2,7 kW
Each
3,6 m³/h
380-400 V
50 Hz
0,6 kW
F
2850 r/min
47 m
BSPP
1 Inch
1 Inch
Each
3,6 m³/h
380-400 V
50 Hz
0,75 kW
F
44
2850 r/min
53,8 m
BSPP
1 Inch
1 Inch
1,9 A
50 Hz
F
430 mm
Cast iron
1.04 kW
40 °C
0 °C
44
2.6 m³/h
Inner thread gas cylindrical (BSPP)
2850 r/min
Electrical
400 V
178 mm
Each
Cast iron
3,4 m³/h
4,8 m³/h
0-400 V
50 Hz
1,02 kW
4,7 A
F
44
2850 r/min
40 °C
0 °C
48,3 m
BSPP
1 Inch
1 Inch
178 mm
414 mm
Electrical
1 kPA
203 mm
Each
4,5 m³/h
380-400 V
50 Hz
1,13 kW
F
44
2850 r/min
60,5 m
BSPP
1-1/4 Inch
1 Inch
Each
10,5 m³/h
380-400 V
50 Hz
1,5 kW
F
44
2850 r/min
46,5 m
BSPP
1-1/2 Inch
1-1/4 Inch
Each
7,2 m³/h
380-400 V
50 Hz
1,88 kW
F
44
2850 r/min
62 m
BSPP
1-1/4 Inch
1 Inch
Each
10,5 m³/h
380-400 V
50 Hz
2,25 kW
F
44
2850 r/min
51 m
BSPP
1-1/2 Inch
1-1/4 Inch
Housing material
Nominal volume flow rate (cubic metre per hour)
Max. volume flow rate (cubic metre per hour)
Cast iron
2,1
3,6
Housing material
Nominal volume flow rate (cubic metre per hour)
Max. volume flow rate (cubic metre per hour)
Cast iron
3,1
4,8
Housing material
Nominal volume flow rate (cubic metre per hour)
Max. volume flow rate (cubic metre per hour)
Cast iron
2,6
3,6
Housing material
Nominal volume flow rate (cubic metre per hour)
Max. volume flow rate (cubic metre per hour)
Cast iron
3,4
4,8
Housing material
Nominal volume flow rate (cubic metre per hour)
Max. volume flow rate (cubic metre per hour)
Cast iron
2,9
4,5
Housing material
Nominal volume flow rate (cubic metre per hour)
Max. volume flow rate (cubic metre per hour)
Cast iron
7,2
10,5
Housing material
Nominal volume flow rate (cubic metre per hour)
Max. volume flow rate (cubic metre per hour)
Cast iron
4,2
7,2
Housing material
Nominal volume flow rate (cubic metre per hour)
Max. volume flow rate (cubic metre per hour)
Cast iron
7,2
10,5
Max. volume flow rate (cubic metre per hour)
Rated voltage (volt)
Frequency (hertz)
3,6
380-400
50
Max. volume flow rate (cubic metre per hour)
Rated voltage (volt)
Frequency (hertz)
3,6
380-400
50
Housing material
Nominal volume flow rate (cubic metre per hour)
Max. volume flow rate (cubic metre per hour)
Cast iron
3,4
4,8
Max. volume flow rate (cubic metre per hour)
Rated voltage (volt)
Frequency (hertz)
4,5
380-400
50
Max. volume flow rate (cubic metre per hour)
Rated voltage (volt)
Frequency (hertz)
10,5
380-400
50
Max. volume flow rate (cubic metre per hour)
Rated voltage (volt)
Frequency (hertz)
7,2
380-400
50
Max. volume flow rate (cubic metre per hour)
Rated voltage (volt)
Frequency (hertz)
10,5
380-400
50