Want to know more about the prices or order directly? This is possible when you are affiliated with a dealer in your area. Do you want to sell products via Kramp as a dealer? Then sign up!
Technical info | PVRES joysticks are weather-proof (protection class IP44). Due to the small dimensions they are specifically designed for panel fitting. This type also has fingertip control and integral flow regulators. Optional accessories can also be supplied. Voltage range: UDC 11 - 30 UDC, Current consumption: < 80 mA, Output voltage Us: 0.25 - 0.75 UDC, Neutral voltage Us: 0.5, Max. signal current UDC = 12 V ± 0.6 mA, UDC = 24 V ± 1.2 mA Show more |
---|
Want to know more about the prices or order directly? This is possible when you are affiliated with a dealer in your area. Do you want to sell products via Kramp as a dealer? Then sign up!
Product | Unit | Number of switch positions | Category | Note | Layout | Type |
---|---|---|---|---|---|---|
Each | 1 | 1x prop | In PVRES 155B4211 two extra flow regulators (potentiometers) are fitted, these can be set independently of each other. The potentiometers limit the signal voltage (Us) and hence influence the flow from the proportional valve to connection A and B without affecting the maximum stroke of the PVRES. In brief you have the complete stroke of the handle while the flow is limited. The flow can be limited to max 25% of max flow. Show more | 1x Proportional | Standard | |
Each | 1 | 1x prop | Neutral position blocking / In PVRES 155B4211 two extra flow regulators (potentiometers) are fitted, these can be set independently of each other. The potentiometers limit the signal voltage (Us) and hence influence the flow from the proportional valve to connection A and B without affecting the maximum stroke of the PVRES. In brief you have the complete stroke of the handle while the flow is limited. The flow can be limited to max 25% of max flow. Show more | 1x Proportional | Neutral position blocking | |
Each | 2 | 2x Proportional | Standard | |||
Each | 1 | 1x prop | In PVRES 155B4211 two extra flow regulators (potentiometers) are fitted, these can be set independently of each other. The potentiometers limit the signal voltage (Us) and hence influence the flow from the proportional valve to connection A and B without affecting the maximum stroke of the PVRES. In brief you have the complete stroke of the handle while the flow is limited. The flow can be limited to max 25% of max flow. Show more | 1x Proportional | Short | |
Each | 2 | In PVRES 155B4211 two extra flow regulators (potentiometers) are fitted, these can be set independently of each other. The potentiometers limit the signal voltage (Us) and hence influence the flow from the proportional valve to connection A and B without affecting the maximum stroke of the PVRES. In brief you have the complete stroke of the handle while the flow is limited. The flow can be limited to max 25% of max flow. Show more | 2x Proportional | Short | ||
Each | 1 | 1x On-off-on | In PVRES 155B4211 two extra flow regulators (potentiometers) are fitted, these can be set independently of each other. The potentiometers limit the signal voltage (Us) and hence influence the flow from the proportional valve to connection A and B without affecting the maximum stroke of the PVRES. In brief you have the complete stroke of the handle while the flow is limited. The flow can be limited to max 25% of max flow. Show more | On-off-on | Standard | |
| ||||||
| ||||||
| ||||||
| ||||||
| ||||||
| ||||||