Technical info
  • Screw terminals
  • Ending SW: complete black, else yellow hood
  • Number has D in code : Contact close before break (delay)
  • First number: amount if NO contacts
  • Second number: amount of NC contacts
  • LSE : Electronic circuit
  • LSE-AI: Analog output 4-20mA
  • LSE-AU: Analog output 0-10V

Interested in buying products?

Want to know more about the prices or order directly? This is possible when you are affiliated with a dealer in your area.

  • Tailored advice from our specialists
  • More than 500.000 products
Product
Unit

Alignment of the control element

Ambient temperature during operating

Construction type housing

Insulation class

Diameter sensor

Explosion safety category for dust

Explosion safety category for gas

Forced opening

Height of sensor

Material housing

Length of sensor

Number of contacts as change-over contact

Number of contacts as normally closed contact

Number of contacts as normally open contact

Number of safety auxiliary contacts

Output electronic

Rated operation current Ie at AC-15, 125 V

Rated operation current Ie at AC-15, 230 V

Rated operation current Ie at AC-15, 24 V

Rated operation current Ie at DC-13, 125 V

Rated operation current Ie at DC-13, 230 V

Rated operation current Ie at DC-13, 24 V

Suitable for safety functions

Switching function

Switching function latching

Type of control element

Type of electric connection

Type of interface

Type of interface for safety communication

Width sensor

With status indication

According to norm

Manufacturer Product ID

Switching capacity (AC-15 230V) (A)

Switching capacity (AC-15 24V)

Switching capacity (AC-15 400V)

Switching capacity (AC-15 115V)

Terminal capacities (mm2)

Number of NC contacts

Number of NO contacts

Protection type

Cable entry

Switching capacity (DC-13 110V)

Switching capacity (DC-13 24V)

Switching capacity (DC-13 220V)

Each
Roller cam straight
-25.0 °C
Cuboid
66 / 67
0 mm
None
None
Yes
61 mm
Plastic
33.5 mm
0
1
1
1
No
6 A
6 A
6 A
0.8 A
0.3 A
3 A
Yes
Quick-break switch
No
Plunger
Cable entry metrical
None
None
31 mm
No
LS,LSM: IEC/EN 60947 / LSE: IEC/EN60947, EN61000-4
106806
6 A
6 A
4 A
6 A
1x (0,5 - 2,5) mm²
1
1
IP66
M20
1 A
10 A
0.5 A
Each
Roller cam straight
-25.0 °C
Cuboid
66 / 67
0 mm
None
None
Yes
61 mm
Plastic
33.5 mm
0
1
1
1
No
6 A
6 A
6 A
0.8 A
0.3 A
3 A
Yes
Quick-break switch
No
Plunger
Cable entry metrical
None
None
31 mm
No
LS,LSM: IEC/EN 60947 / LSE: IEC/EN60947, EN61000-4
106798
6 A
6 A
4 A
6 A
1x (0,5 - 2,5) mm²
1
1
IP66
M20
1 A
10 A
0.5 A
Each
Roller cam straight
-25.0 °C
Cuboid
66 / 67
0 mm
None
None
Yes
61 mm
Plastic
33.5 mm
0
1
1
1
No
6 A
6 A
6 A
0.8 A
0.3 A
3 A
Yes
Slow-action switch
No
Plunger
Cable entry metrical
None
None
31 mm
No
LS,LSM: IEC/EN 60947 / LSE: IEC/EN60947, EN61000-4
106783
6 A
6 A
4 A
6 A
1x (0,5 - 2,5) mm²
1
1
IP66
M20
1 A
10 A
0.5 A
Each
Roller cam straight
-25.0 °C
Cuboid
66 / 67
0 mm
None
None
Yes
61 mm
Plastic
33.5 mm
0
1
1
1
No
6 A
6 A
6 A
0.8 A
0.3 A
3 A
Yes
Slow-action switch
No
Plunger
Cable entry metrical
None
None
31 mm
No
LS,LSM: IEC/EN 60947 / LSE: IEC/EN60947, EN61000-4
106791
6 A
6 A
4 A
6 A
1x (0,5 - 2,5) mm²
1
1
IP66
M20
1 A
10 A
0.5 A
Alignment of the control element
Ambient temperature during operating (degree Celsius)
Construction type housing
Roller cam straight
-25.0
Cuboid
Alignment of the control element
Ambient temperature during operating (degree Celsius)
Construction type housing
Roller cam straight
-25.0
Cuboid
Alignment of the control element
Ambient temperature during operating (degree Celsius)
Construction type housing
Roller cam straight
-25.0
Cuboid
Alignment of the control element
Ambient temperature during operating (degree Celsius)
Construction type housing
Roller cam straight
-25.0
Cuboid