Details | Automatic test sequence for devices of class I (button 1), class II (button 2) and line test (button 3) | |
---|
Application range | - Safety testing of electric devices/equipment, such as power tools, heaters, motorized devices, lights, extension cords, household/office equipment, entertainment electronics and information technology devices, etc.
- RPE, RISO, short-circuit test and continuity test of phase conductor (L) and neutral conductor (N)
| |
---|
Properties | - Testing in accordance with DIN VDE 0701-0702, BGV A3, BetrSichV (German Federal Ordinance on Safety and Health), ÖVE/ÖNORM E8701 and NEN 3140
- Limits preset according to DIN VDE 0701-0702
- Three-phase test specimens can be tested using optional measurement adapter
- Battery capacity (4 x 1.5V AA, IEC LR6) sufficient for 2500 device tests
- Measurement result with good/poor indicator
| |
---|
Consists of | - Carrier bag
- Test line with measuring clamp
- Non-heating appliance line
- Battery set
| |
---|
Technical info | - Appliance Tester – testing of electrical appliances
-
- Application:
- Safety-related testing of electrical devices/ work equipment such as e.g. electric
- tools, motorized equipment, lamps, extension cables, household appliances,
- electrical office machines, consumer electronics and information technology.
-
- Measuring functions:
- protective conductor resistance with a testing current of 200 mA
- insulating resistance with a testing voltage of 500 V
- protective conductor current and contact current by means of alternative
- leakage current measurement method
- voltage measurement on external shock-proof socket (L-N, L-PE, N-PE)
-
- Features:
- automatic testing procedure for devices of class I (key 1), class II/III (key 2)
- and line test (key 3)
- testing of cable reels, multiple distributors and device connecting
- cables with rubber connector
- note in case of incorrect selection of the testing procedure and
- if the test sample is not switched on
- sufficient battery capacity for 2,500 test samples
- limiting values preset in compliance with VDE standard
- three-phase test objects can be tested with differential current measurement
- by means of optional leakage current clamp and measuring adapter
- easy operation for network-independent and mobile testing
| |
---|
Benefits | - Simple operation via 3 buttons
- Test complete within 10 seconds
- Testing can be performed independent of power supply system
| |
---|