Cable, with yellow/green core

Browse to product table
Long description
  • In dry and wet rooms with low mechanical stress. Outdoors only with protected installation. Not in water. As connection and linking cable in measurement and control technology according to DIN VDE 0113.
  • For computer units, control devices on machine tools, assembly and conveyor belts, on conveyors and production lines for the control, regulation and monitoring of work processes and industrial plants.
Product details
  • Conductor
  • Copper, bare, flexible according to DIN VDE 0295:1995-06, class 5
  • Core insulation spec. PVC type YI 2, (polyvinyl chloride)
  • Outer sheath
  • PVC type YM 2 (Polyvinyl chloride), colour grey
  • Core identification
  • according to DIN VDE 0293:1990-01
Product
Unit

Nominal voltage U0

Nominal voltage U

Core cross section

Conductor category class code

Number of cores

Core insultation material

Core identification type

Protective conductor

Screen

Outer sheath material

Supspension element

Outer sheath colour

Torsion resistance

Fire reaction class code according to EN 13501-6

Halogen free according to EN 50267-2-2

Flame retardant according to IEC/EN 60332-1-2

Low smoke according to EN 61034-2

Low temperature resistance according to EN 60811 (504, 505, 506)

Oil resistance acccording to EN 60811-404

Outside diameter

Min. permitted bending radius - moving application (free movement)

Min. permitted bending radius - stationare application (permanent installation)

Assembling ambient temperature range

Working ambient temperature range

Permitted cable outer temperature after assembling without vibration

Content in sale unit

Content in sale unit

Packing type

Additional info

Manufacturer Product ID

Colour outer sheath

Conductor category

Conductor material

Conductor surface

Core identification

Low temperature resistant according to EN 60811-504+505+506

Material core insulation

Material outer sheath

Min. permitted bending radius, moving application/free movement

Min. permitted bending radius, stationary application/permanent installation

Nominal cross section conductor

Nominal voltage U0

Nominal voltage U

Number of cores

Oil resistant according to EN IEC 60811-404

Outer diameter approx.

Permitted cable outer temperature during assembling/handling

Reaction-to-fire according to EN 13501-6: Flaming droplets/particles

Reaction-to-fire according to EN 13501-6: Acidity

Reaction-to-fire according to EN 13501-6: Smoke production

Screen over stranding element

Screen over stranding

Stranding element

Suspension element

Torsion resistant

Metre
300 V
500 V
0.5 mm²
5
3
PVC
Numbers
Yes
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
5.1 mm
39 mm
21 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
*Please note that this item is either a dangerous good or a non-standard delivery size. This means a specialist carrier will be used and this item will take upto 48 hours to deliver.
10002
Metre
300 V
500 V
0.5 mm²
5
4
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
5.5 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10004
Grey
Class 5 = flexible
Copper
None
Numbers
No
PVC
PVC
42 mm
22 mm
0.5 mm²
300 V
500 V
4
No
5.5 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
0.5 mm²
5
5
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
6.2 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10006
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
47 mm
25 mm
0.5 mm²
300 V
500 V
5
No
6.2 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
0.5 mm²
5
7
PVC
Numbers
Yes
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
6.7 mm
51 mm
27 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10009
Metre
300 V
500 V
0.5 mm²
5
10
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
8.6 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10012
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
65 mm
35 mm
0.5 mm²
300 V
500 V
10
No
8.6 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
0.5 mm²
5
12
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
9.1 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10013
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
69 mm
37 mm
0.5 mm²
300 V
500 V
12
No
9.1 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
0.5 mm²
5
18
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
10.7 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10016
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
81 mm
43 mm
0.5 mm²
300 V
500 V
18
No
10.7 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
0.5 mm²
5
25
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
12.6 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10019
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
95 mm
51 mm
0.5 mm²
300 V
500 V
25
No
12.6 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
0.5 mm²
5
40
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
15.3 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10023
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
115 mm
62 mm
0.5 mm²
300 V
500 V
40
No
15.3 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
0.75 mm²
5
3
PVC
Numbers
Yes
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
5.6 mm
42 mm
23 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10031
Metre
300 V
500 V
0.75 mm²
5
4
PVC
Numbers
Yes
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
6.3 mm
48 mm
26 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10033
Metre
300 V
500 V
0.75 mm²
5
5
PVC
Numbers
Yes
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
6.9 mm
52 mm
28 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10035
Metre
300 V
500 V
0.75 mm²
5
7
PVC
Numbers
Yes
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
7.7 mm
58 mm
31 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10038
Metre
300 V
500 V
0.75 mm²
5
8
PVC
Numbers
Yes
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
8.5 mm
64 mm
34 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10040
Metre
300 V
500 V
0.75 mm²
5
10
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
9.8 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10042
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
74 mm
40 mm
0.75 mm²
300 V
500 V
10
No
9.8 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
0.75 mm²
5
12
PVC
Numbers
Yes
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
10.1 mm
76 mm
41 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
*Please note that this item is either a dangerous good or a non-standard delivery size. This means a specialist carrier will be used and this item will take upto 48 hours to deliver.
10043
Metre
300 V
500 V
0.75 mm²
5
18
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
12.2 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10047
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
92 mm
49 mm
0.75 mm²
300 V
500 V
18
No
12.2 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
0.75 mm²
5
21
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
12.8 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10049
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
96 mm
52 mm
0.75 mm²
300 V
500 V
21
No
12.8 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
0.75 mm²
5
25
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
14.3 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10050
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
108 mm
58 mm
0.75 mm²
300 V
500 V
25
No
14.3 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
0.75 mm²
5
34
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
16.7 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10052
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
126 mm
67 mm
0.75 mm²
300 V
500 V
34
No
16.7 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
1 mm²
5
3
PVC
Numbers
Yes
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
6.1 mm
46 mm
25 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10061
Metre
300 V
500 V
1 mm²
5
4
PVC
Numbers
Yes
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
6.7 mm
51 mm
27 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10063
Metre
300 V
500 V
1 mm²
5
5
PVC
Numbers
Yes
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
7.5 mm
57 mm
30 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10065
Metre
300 V
500 V
1 mm²
5
7
PVC
Numbers
Yes
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
8.1 mm
61 mm
33 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10068
Metre
300 V
500 V
1 mm²
5
8
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
9.2 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10070
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
69 mm
37 mm
1 mm²
300 V
500 V
8
No
9.2 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
1 mm²
5
10
PVC
Numbers
Yes
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
10.6 mm
80 mm
43 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10180
Metre
300 V
500 V
1 mm²
5
12
PVC
Numbers
Yes
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
10.9 mm
82 mm
44 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10072
Metre
300 V
500 V
1 mm²
5
16
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
12.3 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10075
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
93 mm
50 mm
1 mm²
300 V
500 V
16
No
12.3 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
1 mm²
5
18
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
12.9 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10076
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
97 mm
52 mm
1 mm²
300 V
500 V
18
No
12.9 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
1 mm²
5
25
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
15.4 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10078
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
116 mm
62 mm
1 mm²
300 V
500 V
25
No
15.4 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
1 mm²
5
34
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
17.9 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10079
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
135 mm
72 mm
1 mm²
300 V
500 V
34
No
17.9 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
1 mm²
5
42
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
19.5 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10083
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
147 mm
78 mm
1 mm²
300 V
500 V
42
No
19.5 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
1 mm²
5
50
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
21.3 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10084
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
160 mm
86 mm
1 mm²
300 V
500 V
50
No
21.3 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
1.5 mm²
5
3
PVC
Numbers
Yes
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
6.8 mm
51 mm
28 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10091
Metre
300 V
500 V
1.5 mm²
5
4
PVC
Numbers
Yes
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
7.6 mm
57 mm
31 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10093
Metre
300 V
500 V
1.5 mm²
5
5
PVC
Numbers
Yes
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
8.3 mm
63 mm
34 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10095
Metre
300 V
500 V
1.5 mm²
5
7
PVC
Numbers
Yes
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
9.2 mm
69 mm
37 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10098
Metre
300 V
500 V
1.5 mm²
5
8
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
10.5 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10100
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
79 mm
42 mm
1.5 mm²
300 V
500 V
8
No
10.5 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
1.5 mm²
5
10
PVC
Numbers
Yes
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
12 mm
90 mm
48 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10181
Metre
300 V
500 V
1.5 mm²
5
12
PVC
Numbers
Yes
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
12.4 mm
93 mm
50 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10103
Metre
300 V
500 V
1.5 mm²
5
18
PVC
Numbers
Yes
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
14.8 mm
111 mm
60 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
*Please note that this item is either a dangerous good or a non-standard delivery size. This means a specialist carrier will be used and this item will take upto 48 hours to deliver.
10107
Metre
300 V
500 V
1.5 mm²
5
25
PVC
Numbers
Yes
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
17.6 mm
132 mm
71 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10110
Metre
300 V
500 V
1.5 mm²
5
34
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
20.2 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10112
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
152 mm
81 mm
1.5 mm²
300 V
500 V
34
No
20.2 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
1.5 mm²
5
42
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
22.2 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10114
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
167 mm
89 mm
1.5 mm²
300 V
500 V
42
No
22.2 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
2.5 mm²
5
3
PVC
Numbers
Yes
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
8.3 mm
63 mm
34 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10121
Metre
300 V
500 V
2.5 mm²
5
4
PVC
Numbers
Yes
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
9.3 mm
70 mm
38 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10123
Metre
300 V
500 V
2.5 mm²
5
5
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
10.1 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10125
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
76 mm
41 mm
2.5 mm²
300 V
500 V
5
No
10.1 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
2.5 mm²
5
7
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
11.2 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10127
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
84 mm
45 mm
2.5 mm²
300 V
500 V
7
No
11.2 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
2.5 mm²
5
12
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
15.3 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10130
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
115 mm
62 mm
2.5 mm²
300 V
500 V
12
No
15.3 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
2.5 mm²
5
14
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
16.2 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10131
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
122 mm
65 mm
2.5 mm²
300 V
500 V
14
No
16.2 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
2.5 mm²
5
25
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
21.6 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10134
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
162 mm
87 mm
2.5 mm²
300 V
500 V
25
No
21.6 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
4 mm²
5
3
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
9.8 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10141
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
74 mm
40 mm
4 mm²
300 V
500 V
3
No
9.8 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
4 mm²
5
4
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
10.9 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10142
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
82 mm
44 mm
4 mm²
300 V
500 V
4
No
10.9 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
4 mm²
5
5
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
12.1 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10143
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
91 mm
49 mm
4 mm²
300 V
500 V
5
No
12.1 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
4 mm²
5
7
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
13.4 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10144
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
101 mm
54 mm
4 mm²
300 V
500 V
7
No
13.4 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
6 mm²
5
4
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
13.2 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10148
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
99 mm
53 mm
6 mm²
300 V
500 V
4
No
13.2 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
6 mm²
5
5
PVC
Numbers
Yes
PVC
Yes
Grey
Eca
No
Yes
No
14.7 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10149
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
111 mm
59 mm
6 mm²
300 V
500 V
5
No
14.7 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.75
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.75
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.75
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.75
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.75
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.75
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.75
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.75
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.75
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.75
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.75
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
2.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
2.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
2.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
2.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
2.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
2.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
2.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
4
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
4
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
4
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
4
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
6
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
6