Cable, without yellow/green core

Browse to product table
Technical info
  • Approval Certificates
  • VDE Reg N° 7691
  • Application
  • In dry and moist rooms for light mechanical stresses. Outdoors only when protected. Not in water. As supply and interconnecting cable for measuring, controlling and regulating acc. to DIN VDE 0113. For computer units, control equipments on machine tools assembly lines, conveyors and production lines for controlling, regulating and monotoring work processes, industrial plants and production lines when temporarily freely moved and no periodic recurrence without forced guidance. Cross sections above 10 mm² are energy supply cable for fixed installations on machine tools in production lines.
  • Design
  • Conductor
  • Copper bare stranded, VDE 0295 Class 5
  • Insulation
  • PVC Type YI 2 (Polyvinyl chloride)
  • Outer sheath
  • PVC Type YM 2 (Polyvinyl chloride), colour grey,
  • Core identification
  • according to DIN VDE 0293:1990-01
  • JZ/OZ: black, white printed numbers and with/or without green/yellow core
  • JB: coloured cores according to HD 308 S2
Product
Unit

Nominal voltage U0

Nominal voltage U

Core cross section

Conductor category class code

Number of cores

Core insultation material

Core identification type

Protective conductor

Screen

Outer sheath material

Supspension element

Outer sheath colour

Torsion resistance

Fire reaction class code according to EN 13501-6

Halogen free according to EN 50267-2-2

Flame retardant according to IEC/EN 60332-1-2

Low smoke according to EN 61034-2

Low temperature resistance according to EN 60811 (504, 505, 506)

Oil resistance acccording to EN 60811-404

Outside diameter

Min. permitted bending radius - moving application (free movement)

Min. permitted bending radius - stationare application (permanent installation)

Assembling ambient temperature range

Working ambient temperature range

Permitted cable outer temperature after assembling without vibration

Content in sale unit

Content in sale unit

Packing type

Manufacturer Product ID

Colour outer sheath

Conductor category

Conductor material

Conductor surface

Core identification

Low temperature resistant according to EN 60811-504+505+506

Material core insulation

Material outer sheath

Min. permitted bending radius, moving application/free movement

Min. permitted bending radius, stationary application/permanent installation

Nominal cross section conductor

Nominal voltage U0

Nominal voltage U

Number of cores

Oil resistant according to EN IEC 60811-404

Outer diameter approx.

Permitted cable outer temperature during assembling/handling

Reaction-to-fire according to EN 13501-6: Flaming droplets/particles

Reaction-to-fire according to EN 13501-6: Acidity

Reaction-to-fire according to EN 13501-6: Smoke production

Screen over stranding element

Screen over stranding

Stranding element

Suspension element

Torsion resistant

Metre
300 V
500 V
0.5 mm²
5
2
PVC
Numbers
No
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
4.8 mm
36 mm
20 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10001
Metre
300 V
500 V
0.5 mm²
5
3
PVC
Numbers
No
PVC
Yes
Grey
Eca
No
Yes
No
5.1 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10003
Grey
Class 5 = flexible
Copper
None
Numbers
No
PVC
PVC
39 mm
21 mm
0.5 mm²
300 V
500 V
3
No
5.1 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
0.75 mm²
5
2
PVC
Numbers
No
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
5.3 mm
40 mm
22 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10030
Metre
300 V
500 V
0.75 mm²
5
3
PVC
Numbers
No
PVC
Yes
Grey
Eca
No
Yes
No
5.6 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10032
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
42 mm
23 mm
0.75 mm²
300 V
500 V
3
No
5.6 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
0.75 mm²
5
4
PVC
Numbers
No
PVC
Yes
Grey
Eca
No
Yes
No
6.3 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10034
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
48 mm
26 mm
0.75 mm²
300 V
500 V
4
No
6.3 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Metre
300 V
500 V
1 mm²
5
2
PVC
Numbers
No
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
5.6 mm
42 mm
23 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10060
Metre
300 V
500 V
1.5 mm²
5
2
PVC
Numbers
No
No
PVC
Yes
Grey
No
Eca
No
Yes
No
No
No
6.4 mm
48 mm
26 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10090
Metre
300 V
500 V
2.5 mm²
5
2
PVC
Numbers
No
PVC
Yes
Grey
Eca
No
Yes
No
7.8 mm
-40-80 °C
-15-80
-40.0-80.0
1 m
1 pcs
n/a
10120
Grey
Class 5 = flexible
Numbers
No
PVC
PVC
59 mm
32 mm
2.5 mm²
300 V
500 V
2
No
7.8 mm
-15.0-80.0 °C
None
None
None
None
None
No
n/a
No
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.75
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.75
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
0.75
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
1.5
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
2.5