Gegenhalteventile_allg_Info_DEDownloads
Long description | Equalising valves or brake valves provide controlled movement, stopping and holding of loads. They prevent the lag of movements (negative load) and protect the installation against external forces (anti-shock). Overcentre valves provide controlled initiation and stopping of a movement, while holding the load at rest. When mounted directly on the cylinder or motor, they also function as hose breakage protection. Show more | |
---|---|---|
Pros |
| |
Product details |
| |
Includes |
|
Product | Unit | Designed for | Flow rate | Length under head B | Pressure max. | A (mm) | Opening pressure spring (bar) | Torque Nm | Note | Pressure range | Pilot ratio | Seal | Size | Wrench size SW1 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Each | As a safety component when, in single or double action systems, cylinders or motors must remain fixed in any desired position. External forces may not affect the position. | 114 l/min | 55.9 mm | 345 BAR | 97 mm | 1 | 115 - 122 N·m | Stable, quiet and precise function. The value set should always be 30% higher than the maximum load pressure. | 34 - 103 BAR | 1 : 4,5 | Order no.: with code CP 9-4.12.003 | CP12-3S Inch | 31.8 mm | |
| ||||||
Gegenhalteventile_allg_Info_DEDownloads