EMC Cable

Browse to product table
Long description
EMC Cable
Technical info
  • Approval certificates
  • Adapted to VDE 250
  • Application
  • Especially for frequency converter controlled AC drives. For fixed installation and occasional free flexing indoors in dry, damp and wet conditiones, as well as outdoor (separate black version) for low mechanical stress. Not suitable for the installation direct in ground and in water. Cores are normally identified by colours according to HD 308 S2.
  • Design:
  • Conductor:
  • plain finely stranded copper, Class 5 according to VDE 0295 or IEC 60228
  • Protective Conductor:
  • plain finely stranded copper, Class 5 according to VDE 0295 or IEC 60228 - for cross sections > 16mm² the protective conductor is divided into 3 cores
  • Insulation:
  • halogen free special XLPE according to IEC 60502-4 max. core temperature: 90C°
  • Screen:
  • Multilayer screen, EMC - optimized regarding to radio frequency interference field strength and voltage according to EN 55011 or DIN VDE 0875
  • 1. Layer: Al - coated tape
  • 2. Layer: braid of tinned copper wires
  • Outer Sheath:
  • PVC Type YM 2 (polyviny chloride) according to VDE 0207 Part 5,
  • optional also available with halogen free outer sheath SHF1 (HM2) according to IEC 60092-353 (2XSLSTCH-J)
  • Colour: grey (standard PVC), optional black or transparent
  • Core identification:
  • Colour: according to HD 308 S2
Product
Unit

Nominal voltage U0

Nominal voltage U

Core cross section

Conductor category class code

Number of cores

Core insultation material

Core identification type

Protective conductor

Type of screen over stranding

Outer sheath material

Supspension element

Outer sheath colour

Halogen free according to EN 50267-2-2

Flame retardant according to IEC/EN 60332-1-2

Low smoke according to EN 61034-2

Outside diameter

Assembling ambient temperature range

Working ambient temperature range

Content in sale unit

Content in sale unit

Packing type

Rated current

Resistance

Manufacturer Product ID

Nominal cross section conductor

Nominal voltage U

Number of cores

Metre
300 V
500 V
6 mm²
5
4
PVC
Numbers
Yes
Braiding
PVC
Yes
Grey
No
Yes
No
14.2 mm
-40-80 °C
-10-80
1 m
1 pcs
n/a
Metre
600 V
1000 V
1.5 mm²
5
4
Polyethylene
Colours
Yes
Braiding
PVC
Yes
Grey
No
Yes
No
10.1 mm
-40-80 °C
-5-80
1 m
1 pcs
n/a
18 A
13.3 Ω
22234
1.5 mm²
1 V
4
Metre
600 V
1000 V
2.5 mm²
5
4
PVC
Numbers
Yes
Braiding
PVC
Yes
Grey
No
Yes
No
10 mm
-40-80 °C
-10-80
1 m
1 pcs
n/a
26 A
7.98 Ω
22235
2.5 mm²
1 V
4
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Core cross section (square millimetre)
300
500
6
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Rated current (ampere)
600
1000
18
Nominal voltage U0 (volt)
Nominal voltage U (volt)
Rated current (ampere)
600
1000
26